SET90C TAMIAS

Telemanagement for sustainable projects

Telemanagement for sustainable projects


Product description

SET90C TAMIAS is a control unit from the SET90 range that offers a high-performance solution in telemanagement lighting. It also provides a new range of smart functions which guarantee a high level of features, quality and efficiency.

Besides, it incorporates the LINE CONTROL technology to configure the operation and dimming of the luminaires with top brand drivers (Tridonic with U6Me2 and Philips Xitanium with Coded Mains technology) and nodes (Vossloh-Schwabe iMCU), sending codes or signals through its existing electrical infrastructure. Furthermore, with Tridonic's dual-channel output multi-channel drivers, it is possible to configure the color temperature.

Through its peripheral port, it allows centralized control and supervision of the differential switch of automatic self-reclosing devices with communications. In addition, it notifies in real time of the reconnections or interlocking of these.

SET90C TAMIAS offers in a single control unit the measurement of the main electrical parameters of the installation in three-phase networks and single-phase networks. Furthermore, it provides the programming of switching on the circuits through its different relay outputs, as well as the monitoring and management of its alarm inputs. Together with the TELEASTRO system, it will allow you to know in real-time alerts and the status of the installation.

Energy meters provide a timer function that allows fixing the different closures of charging periods while registering the maximum power in each period. This information is managed from the TELEASTRO system, which has tools for energy management and analysis, allowing to know the amount of energy consumed in each period, also making graphs to ease the study of consumption, as well as visualizing simulations of the energy cost and CO2 footprint.

Features

  • Analyzer of a three-phase network or three independent single-phase networks.
  • Record the measurements for each phase of voltage, current, active power, reactive power and power factor.
  • Configurable measurement recording period (fourth hour by default).
  • Record of total active and reactive energy meters in single-phase value for each phase and the total three-phase component.
  • Recording the installation's differential current measurement using the RMA25.
  • Up to eight configurable digital inputs for detection of installation alarms: differentials, circuit breakers, etc.
  • Tamper detection of the cabinet door and the installation in manual mode.
  • Alarm notification by SMS and email.
  • Relay outputs for command and actuation of the installation's manoeuvring circuits.
  • Schedule programming for manoeuvres by type of day of the week.
  • Programming of 40 holidays/special days by type of day of the week.
  • Remote control of the manoeuvring circuits locally or remotely.
  • Clock with synchronization by Timerserver and automatic summer/winter time change.
  • Function for configuring the luminosity of Vossloh-Schwabe iMCU nodes, Tridonic (U6Me2) drivers and Xitanium Philips drivers with Coded Mains technology, and configure the color temperature with Tridonic's dual-channel output multi-channel drivers.
  • Time configuration to set closures of charging periods and maximeter registration.

Related products

TRT20-40

TRT20-40

Single-phase efficient current transformer

  • Inner diameter Ø: 20 mm
  • Primary current measurement: 40 A
  • Transformation ratio: .../200 mA
  • Clip for DIN rail mounting
SET GPRS+

SET GPRS+

Quad Band GPRS modem with power outage warning

  • Electric supply cut control
  • Configurable SMS or email notification
  • Micro-SIM card reader
  • Power supply 85 - 265 V a.c.
  • DIN rail mounting
SET GPRS

SET GPRS

Quad Band GPRS communication modem

  • SMA female external antenna connector
  • RS232 data interface
  • Micro-SIM card reader
  • Power supply 85 - 265 V a.c.
  • DIN rail mounting

Technical specifications

  • 3 Voltage Measurement Inputs (phase-neutral) of 0-260 V a.c. in true effective value.
  • 3 Current Measurement Inputs up to 2500 A, through x/0,2 A a.c. transformers
  • 1 Analog input 0-2 V d.c. for sensor.
  • 6 relay outputs N.C. 5 A for action on installation circuits.
  • 8 digital inputs, by contact or NPN detector at 24 V d.c., for alarm control.
  • 1 RS232 port for SET GPRS or SET GPRS+ modem.
  • 1 RS485 port for resettable differentials or other peripherals.
  • Backlit LCD display.
  • Keyboard and LEDs to indicate the status of the equipment.
  • Internal clock with lithium battery.
  • Supply voltage 230 V a.c. 15%, 50/60 Hz and consumption of 9 VA.
  • 8-module DIN box for trans-panel or symmetrical DIN rail.
  • Dimensions 140 x 110 x 76 mm and weight 650 gr.

    Downloads

    Datasheets and Brochure

Request commercial information
c/ Provença, 533 Local A - 08025 Barcelona (Spain)
Tel. (+34) 934 463 050